Model 106C | 1064 nm Optical Module
Models 090 and 106C provide operating capabilities unavailable from other 904 nm and 1064 nm optical sources. Among them, repetition rates to 100 MHz and precision control of amplitude and time domain.
Combined with the BNC Model 6040 Mainframe, these modules generate fast pulses, subnanosecond impulses, and CW light while maintaining the excellent timing accuracy, low jitter, and nanosecond resolution of the mainframe. In addition, the 090 and 106C have two inputs for stimulus from external signal sources: External Drive and External Modulation.
With External Drive, the optical outputs are fast edge speed, flat-top pulses corresponding to the input signal timing. In External Modulation, an electrical signal is converted into an analog optical form. Thus, it is now possible to transform signals from instruments such as a function or arbitrary waveform generator into their optical equivalents at 904 nm and 1064 nm as well as the other wavelengths described in the Model 6040 product bulletin.
Overview
Features
- Trigger Internal 0.01 Hz to 100 MHz; external 0 to 100 MHz
- Pulse Width 3 ns to 640 s
- Impulse 700 ps (typical)
- Delay 0 ns to 640 s
Applications
- Photo Multiplier
- Photo Detector
- Fiber Optics Testing
Specifications
Light Out
Spectral Peak
1064nm +/- 30nm
Spectral Width
Less than 5nm
Power Level
1mW with adjustable Peak and Baseline levels. *contact factory for higher power up to 10mW
Resolution
100 uW
Transition Times (10% to 90%)
1ns rise time, 2ns fall time.
Dynamic Range
13 dB.
Absolute Accuracy
± 1 dB
Fiber
6/125 Single Mode Fiber is Standard, Contact Factory for Custom
Connector
FC is Standard, Contact Factory for Custom
* Contact factory for customization ( Wavelength, Power, Fiber type, and Connector)
Timing
Rep Rate
Internal 0.01 Hz to 100 MHz; external 0 to 100 MHz.
Pulse Width
Internal 3 ns to 640 s.
Impulse
700 ps typical (fixed).
Delay
0 to 640 s (plus fixed delay)
External Drive
0 to 100 MHz; 300 mV minimum amplitude; 50 Ω input.
External Modulation
100 Hz to 200 MHz ( 3 dB); 100 mVrms/mW sensitivity (typical); 50 Ω input.
Storage
A ROM determines the instrument’s allowable operating conditions and units of display applicable for the installed module.
A nonvolatile memory (RAM) in each module stores up to ten complete settings of operating conditions and output pulse parameters (trigger level, delay, width, etc.).
Recall
The RAM-stored settings can be manually or bus transferred to the mainframe to produce the predetermined outputs.
Weight
Weight
2 Ibs net (0.9 kg); 5 Ibs shipping (2.3 kg)
est. 24 lbs. shipping when installed in Model 6040
Operating Temperature
Same as Model 6040
Technical Resources
Downloadable Resources
Downloadable resources such as datasheets, firmware, software, drivers and products manuals. Alternatively, you can browse resources directly by visiting our downloads page.
Price Lists
Price lists are available to our registered users. To view pricing for this and other products, please log in or create a free account.