A multi-channel vector signal generator covering 10 MHz to 40 GHz continuously, with an internal I/Q modulator, 400 MHz of RF modulation bandwidth, and Pulse Descriptor Word playback (Option PDW) that sets frequency, power, phase, and pulse width on an 8 ns grid. Up to four phase-coherent channels fit in one 2U chassis.

Berkeley Nucleonics Model 875 vector signal generator, single-channel desktop unit

Pictured: Model 875 single-channel desktop unit with a Type N output. The 875-X models are 2U rackmount units with up to four channels.

10 MHz–40 GHz
Continuous coverage
400 MHz
RF modulation bandwidth
8 ns
PDW timing resolution
1–4
Phase-coherent channels

Pick your model, tell us what you need.

A few checkboxes, your name and your email. That is the whole form.

1Top frequency
2Channels
3Options of interest
4What would help most

Your request goes straight to the Berkeley Nucleonics RF team.

Five frequency models. One platform.

Pick the frequency ceiling, then choose a single-channel desktop unit or a 2U rackmount with up to four phase-coherent channels (the -X models).

ModelFrequency rangeSettable up toRF output connector
875-0410 MHz to 4 GHz4.15 GHzType N (F)
875-0610 MHz to 6 GHz6.6 GHzType N (F)
875-1210 MHz to 12 GHz12 GHzType N (F)
875-2010 MHz to 20 GHz20 GHzSMA (F)
875-4010 MHz to 40 GHz43.5 GHzK (2.92 mm) (F)

Specified where timing actually matters.

Frequency range
10 MHz – 40 GHz
100 kHz low end with Option 100K; 0.001 Hz resolution
RF modulation bandwidth
400 MHz
Internal I/Q modulator; 16-bit baseband at up to 500 MHz sample rate
I/Q waveform memory
512 MS
32 bits per I/Q sample; up to 65 k segments
Switching time
500 µs standard
1 µs (875-04) or 2 µs (875-20 / -40) with Option UFS
Phase noise at 1 GHz
−130 dBc/Hz
1 kHz offset, +10 dBm; −87 dBc/Hz at 10 Hz, −98 dBc/Hz with Option LN (typical)
Channel isolation
> 90 dB
Channel-to-channel jitter ±10 ps typical
Pulse modulation
5 ns rise / fall
Typical, with Option MOD; 90 dB on/off ratio on the baseband pulse modulator
Frequency reference
OCXO, ±10 ppb
Initial calibrated accuracy; phase-lockable to an external reference

Specifications reproduced from the Model 875 datasheet (V1.32) as published at berkeleynucleonics.com. Typical values are not warranted performance; PDW, UFS, SYNC, MOD, FCP, and AVIO are options.

Where the 875 goes to work.

Radar signal simulation
each channel can run its own independent PDW simulation, and multiple PDW sequences play back with phase coherence and accurate timing.

EW and receiver testing
up to four coherent emitters from one 2U chassis, with Option SYNC linking multiple units while keeping phase coherence across them.

Avionics modulation emulation
DME, VOR, ILS localizer and glideslope, and marker beacon signals with Option AVIO.

Arbitrary I/Q and antenna testing
play stored I/Q waveforms from memory, or stream I/Q data live through the fast control port (Option FCP) for high-speed antenna and receiver work.

Put the whole scene on the bench.

Talk to a Berkeley Nucleonics RF engineer about the Model 875 configuration for your test program.

Request a demo, quote or engineer chat Or call 800-234-7858