GFT644 | 4 Channel 50 Ω TTL Line Driver Module

You are here:

GFT644 | 4 Channel 50 Ω TTL Line Driver Module

The GFT644 module is specially designed for interfacing signal and 50 Ω long cable.

The input threshold can be set to 1.5 or 0.0 or -1.5 V and the input load can be selected from 50 Ω to 1 KΩ pull up by a front panel switch. So that channel input can be driven directly by TTL / CMOS logic levels or open collector or negative pulse ( 0 to -2 V) or AC coupled signal ( +0.5 to -0.5 V)

All outputs with 50 Ω load can drive 100 feet of cable at clock rate greater than 200 MHz with 2.5 V amplitude. Each output polarity can be set normal or inverted and is compatible with DC or AC TTL input.

The GFT644 is a compact module supplied with a +5V AC/DC adapter

Typical GFT644 application includes to distribute four independent High speed signals to four devices via long cable (up to 100 feet) with TTL level.

Overview

Features
  • Up to 200 MHz clock rate
  • Drive 100 feet of cable at 200 MHz  
  • Four independent inputs with:
    • Selectable threshold (+1 or  0 or  -1 V)
    • Selectable internal load ( 50 Ω or 1 kΩ pull up)
  • Four 50 Ω TTL outputs with:
    • Selectable  polarity (Normal or Inverted)
    • 1 ns typical output rise & fall time
    • 10 ps input to output RMS jitter
  • Operate from DC +5 V
  • Compact module: 115 x 80 x 30 mm
Applications
  • High speed digital communication
  • High to low Impedance converter
  • Pulse inverter
  • Level translator
  • Sine to square wave converter
  • Long line Drivers
  • Tools for lab
  • Components Test equipment

Specifications

Input

Number

4

Range

+5 V to -5 V (max.)

Threshold Level

Preset to -1 V or 0 V or +1 V

Internal Load

Adjustable to 50 Ω or 1 kΩ pulled up to +5 V

Minimum Pulse Width

5 ns

Output

Number

4

Output Resistance

50 Ω

Low Level

0.5 V

High Level

2.5 V @ Load=50 Ω, 4 V @ Load > 10 kΩ

Rise/Fall Times

1 ns / 1ns @ 100 MHz square wave

Polarity From Input

Normal or Inverted

Jitter RMS

10 ps (Input to output)

Max Clock Frequency

200 MHz @ cable length = 3 feet

200 MHz @ cable length = 100 feet

Skew

500 ps (TBC)

General Specifications

Control

Switches to select:

  • input load (common)
  • input threshold (common)
  • Output mode: normal or inverted (individual)

Power on Indicator

Inputs & Outputs

All are BNC connectors

Size

W=115, L=80, H=30 mm

Power V/A

+5 V / 200 mA max.
External AC (90 -240 V) to DC (+ 5 V) adapter furnished

Power Connector

Jack 2.10 mm

Option

GFT614 Module

1 input to 4 Line 50 Ω Driver Module

Technical Resources

Frequently Asked Questions (FAQ)

Downloadable Resources

Downloadable resources such as datasheets, firmware, software, drivers and products manuals. Alternatively, you can browse resources directly by visiting our downloads page.

Price Lists

Price lists are available to our registered users. To view pricing for this and other products, please log in or create a free account.