---
title: "PVM-1001 | ±950V Fast Rise-Time OEM Pulse Generator Module"
date: 2024-12-17T04:58:09Z
modified: 2026-02-12T19:08:17Z
permalink: "https://www.berkeleynucleonics.com/pvm-1001-%c2%b1950v-fast-rise-time/"
type: page
status: publish
excerpt: ""
wpid: 18751
---

[ ![](https://www.berkeleynucleonics.com/wp-content/uploads/banner_configurator_pulsers.png) ](/high-voltage-pulse-generators-standard-and-custom-versions-available)
 [](https://www.berkeleynucleonics.com/wp-content/uploads/pvm-1001_22.png)

![pvm-1001_22](https://www.berkeleynucleonics.com/wp-content/uploads/pvm-1001_22.png)

[](https://www.berkeleynucleonics.com/wp-content/uploads/pvm_1001_front2.png)

![pvm_1001_front2](https://www.berkeleynucleonics.com/wp-content/uploads/pvm_1001_front2.png)

[](https://www.berkeleynucleonics.com/wp-content/uploads/1001-back.png)

![1001-back](https://www.berkeleynucleonics.com/wp-content/uploads/1001-back.png)

- [ 
     Quote
     ](/get-quote/?interested_product=PVM-1001%20|%20%C2%B1950V%20Fast%20Rise-Time)
- [ 
     Contact
     ](/contact-us/)
- [ 
     Datasheet
     ](#bnc-tab-technical-resources)
- [ 
     Price List
     ](/access-pricelist/)
- [ 
     RF Selection Guide
     ](/ProductSelection/)

#### PVM-1001 | ±950V Fast Rise-Time
OEM Pulse Generator Module

The PVM-1001 adjustable pulsed voltage source can drive a 50 ohm resistive load from 0 V to 950 V in less than 10 ns (Rise Time). Pulse widths can range from 55 ns to 10 us with repetition rates to 1 MHz (bursts to 5 MHz). Typical applications include instrument calibration, component testing, beam steering, Time-of-flight mass spectrometry, and PMT and MCP gating. An external trigger source controls the output pulse width and frequency.

Two models are available: the PVM-1001-P produces positive voltage pulses and requires an external positive high voltage power supply. The PVM-1001-N produces negative pulses and requires a negative supply.

The front panel has an SMB connector for the trigger input and a connector for the AC-to-DC converter. The rear panel has MHV connectors for high voltage input and pulsed high voltage output.

 [ ![](data:image/svg+xml;charset=utf-8,%3Csvg xmlns%3D'http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg' viewBox%3D'0 0 1105 100'%2F%3E) ](https://academy.berkeleynucleonics.com/)
 
 Overview
 
 
 Specifications
 
 
 Accessories
 
 
 Technical Resources
 
 
 Downloadable Resources
 
 
 Media
 
 
 Price Lists

##### Applications

Typical applications are instrument calibration, componenet testing, beam steering and PMT and MCP gating.

##### Features

- Output Voltage Range 0V to 950V
- Frequency Range ≤ 5MHz
- Trigger Pulse Width 55ns ≤ Pulse Width ≤ 10,000ns
- Rise Time ≤ 8ns @ 200V to 950V
- Positive or Negative polarity modules available
- Maximum Output Power 208W
- Simple to set up and use

**Maximum Voltage Amplitude**

950V

**Maximum Frequency (MHz)**

≤ 1 MHz (≤ 5 MHz Burst)

**Rise/Fall Time**

9ns

**Pulse Engine (Trigger)**

External

**Pulse Polarity**

Negative (-) or Positive (+)

**Remote Control**

N/A

**Form Factor**

Module

**Dimensions (in)**

14x14x9

**Weight (lbs)**

4.5

 ![](https://www.berkeleynucleonics.com/wp-content/uploads/pvm_1001_output_graphs-01_0-1024x846.png)

##### PVM-1001 Box Contents

Qty

Part Number

Description

1

PVM-100

PVM-1001 Serialized Unit

1

Operating Manual

Operating Manual for PVM-1001

1

AC/DC Plug

Plug AC Interchange All Countries

1

AC/DC Wall Mount

AC/DC Wall Mount Adapter 12V 12W

##### Accessories available for the PVM-1001 module:

- PVA-1001 Input and Output Cables

##### Input and Output Cable Drawings

 ![](https://www.berkeleynucleonics.com/wp-content/uploads/pvm_1001_accessories_input_and_outut_cable_drawings.png)
 ![](https://www.berkeleynucleonics.com/wp-content/uploads/pvm_1001_accessories_input_and_outut_cable_drawings_2.png)

##### Front Panel Features

 ![](https://www.berkeleynucleonics.com/wp-content/uploads/pvm_1001_front_panel_features.png)

##### Support Power Input

Support power input using the 12 VDC adapter, which is provided with the module.

##### Trigger Input

Use the SMB connector with 50 Ω termination for the External trigger input.

##### Air Vents

Keep the vents clear for cooling.

##### Cooling Fans

There are cooling fans on the top of the module. Please keep the top of the module clear for cooling.

##### Rear Panel Features

 ![](https://www.berkeleynucleonics.com/wp-content/uploads/pvm_1001_rear_panel_features.png)

##### Positive or Negative Input Connection

High voltage input using an MHV connector. Positive or Negative depends on which module was purchased. Do NOT plug the incorrect polarity into the module.

##### Output Connection

Pulsed voltage output using an MHV connector.

 [ PVM-1001 Datasheet](https://www.berkeleynucleonics.com/download/22068/?tmstv=1770923297)

Downloadable resources such as datasheets, firmware, software, drivers and products manuals. Alternatively, you can browse resources directly by visiting our [downloads page](/downloads).

- [Product Datasheets](/downloads#tm-datasheets)
- [Product Firmware](/downloads#ddg-firmware)
- [Product Software and Drivers](/downloads#tm-softwaredrivers)
- [Product Manuals](/downloads#tm-manuals)

## Playlist

 
 ![BNC | High Voltage Webinar! Introducing Pulsed Power](https://img.youtube.com/vi/8OcFVux2tsQ/maxresdefault.jpg)

####  BNC | High Voltage Webinar! Introducing Pulsed Power
 

 59:03
 ![DEI Quick Tip Defining Pulse Width and Rise Time Rev 2019](https://img.youtube.com/vi/PP9Ryse8I2U/maxresdefault.jpg)

####  DEI Quick Tip Defining Pulse Width and Rise Time Rev 2019
 

 3:10
 ![DEI Quick Tip Gates vs  Triggers for Electronic Instruments Rev 2019](https://img.youtube.com/vi/POEKUbwsma4/maxresdefault.jpg)

####  DEI Quick Tip Gates vs Triggers for Electronic Instruments Rev 2019
 

 3:25
 ![High Voltage Power Supply & Pulse Generator Webinar! What You Need to Know](https://img.youtube.com/vi/E8cJDr2VDRM/maxresdefault.jpg)

####  High Voltage Power Supply & Pulse Generator Webinar! What You Need to Know
 

 44:38

 [ Berkeley Nucleonics Price List 2024](https://www.berkeleynucleonics.com/download/19881/?tmstv=1770923297)

##### Applications

Typical applications are instrument calibration, componenet testing, beam steering and PMT and MCP gating.

##### Features

- Output Voltage Range 0V to 950V
- Frequency Range ≤ 5MHz
- Trigger Pulse Width 55ns ≤ Pulse Width ≤ 10,000ns
- Rise Time ≤ 8ns @ 200V to 950V
- Positive or Negative polarity modules available
- Maximum Output Power 208W
- Simple to set up and use

**Maximum Voltage Amplitude**

950V

**Maximum Frequency (MHz)**

≤ 1 MHz (≤ 5 MHz Burst)

**Rise/Fall Time**

9ns

**Pulse Engine (Trigger)**

External

**Pulse Polarity**

Negative (-) or Positive (+)

**Remote Control**

N/A

**Form Factor**

Module

**Dimensions (in)**

14x14x9

**Weight (lbs)**

4.5

 ![](https://www.berkeleynucleonics.com/wp-content/uploads/pvm_1001_output_graphs-01_0-1024x846.png)

##### PVM-1001 Box Contents

Qty

Part Number

Description

1

PVM-100

PVM-1001 Serialized Unit

1

Operating Manual

Operating Manual for PVM-1001

1

AC/DC Plug

Plug AC Interchange All Countries

1

AC/DC Wall Mount

AC/DC Wall Mount Adapter 12V 12W

##### Accessories available for the PVM-1001 module:

- PVA-1001 Input and Output Cables

##### Input and Output Cable Drawings

 ![](https://www.berkeleynucleonics.com/wp-content/uploads/pvm_1001_accessories_input_and_outut_cable_drawings.png)
 ![](https://www.berkeleynucleonics.com/wp-content/uploads/pvm_1001_accessories_input_and_outut_cable_drawings_2.png)

##### Front Panel Features

 ![](https://www.berkeleynucleonics.com/wp-content/uploads/pvm_1001_front_panel_features.png)

##### Support Power Input

Support power input using the 12 VDC adapter, which is provided with the module.

##### Trigger Input

Use the SMB connector with 50 Ω termination for the External trigger input.

##### Air Vents

Keep the vents clear for cooling.

##### Cooling Fans

There are cooling fans on the top of the module. Please keep the top of the module clear for cooling.

##### Rear Panel Features

 ![](https://www.berkeleynucleonics.com/wp-content/uploads/pvm_1001_rear_panel_features.png)

##### Positive or Negative Input Connection

High voltage input using an MHV connector. Positive or Negative depends on which module was purchased. Do NOT plug the incorrect polarity into the module.

##### Output Connection

Pulsed voltage output using an MHV connector.

[ PVM-1001 Datasheet](https://www.berkeleynucleonics.com/download/22068/?tmstv=1778700933)Downloadable resources such as datasheets, firmware, software, drivers and products manuals. Alternatively, you can browse resources directly by visiting our [downloads page](/downloads).

- [Product Datasheets](/downloads#tm-datasheets)
- [Product Firmware](/downloads#ddg-firmware)
- [Product Software and Drivers](/downloads#tm-softwaredrivers)
- [Product Manuals](/downloads#tm-manuals)

## Playlist

 
 ![BNC | High Voltage Webinar! Introducing Pulsed Power](https://img.youtube.com/vi/8OcFVux2tsQ/maxresdefault.jpg)

####  BNC | High Voltage Webinar! Introducing Pulsed Power
 

 59:03
 ![DEI Quick Tip Defining Pulse Width and Rise Time Rev 2019](https://img.youtube.com/vi/PP9Ryse8I2U/maxresdefault.jpg)

####  DEI Quick Tip Defining Pulse Width and Rise Time Rev 2019
 

 3:10
 ![DEI Quick Tip Gates vs  Triggers for Electronic Instruments Rev 2019](https://img.youtube.com/vi/POEKUbwsma4/maxresdefault.jpg)

####  DEI Quick Tip Gates vs Triggers for Electronic Instruments Rev 2019
 

 3:25
 ![High Voltage Power Supply & Pulse Generator Webinar! What You Need to Know](https://img.youtube.com/vi/E8cJDr2VDRM/maxresdefault.jpg)

####  High Voltage Power Supply & Pulse Generator Webinar! What You Need to Know
 

 44:38

 [ Berkeley Nucleonics Price List 2026](https://www.berkeleynucleonics.com/download/19881/?tmstv=1778700933)



 [ ![](data:image/svg+xml;charset=utf-8,%3Csvg xmlns%3D'http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg' viewBox%3D'0 0 1105 130'%2F%3E) ](/products/microwave-rf-signal-generators)