DC OUTPUT VOLTAGES
±6 V, 8 A each; ±12 V, 2 A each; ±24 V, 1 A each. Total combined DC output
not to exceed 132 VA. DC Voltages have a ±2% adjustment range.
REGULATION
Less than ±0.1% for ±12 V and ±24 V, ±0.2% for ± 6 V over line voltage variation
of ±10% or ±100% changes in rated load.
RIPPLE AND NOISE
Less than 3 mV peak-to-peak as observed on a 50 MHz bandwidth scope.
RECOVERY TIME AND STABILITY
Recovery: Less than 100 µs return with regulation limits for 10% to 100
% step-change in rated load.
Stability: After 1 hr. warmup ±0.5% for 6 months at constant load, line
and ambient.
CIRCUIT PROTECTION
Fully protected against short circuits or overloads by foldback circuitry.
THERMAL PROTECTION
Thermal warning light activates if supply temperature exceeds 60°C. Power
is interrupted if interior temperature exceeds safe limits.
MODULE CONNECTORS
AMP 202516-3 (or equiv.) connectors wired to DC output busses, high quality
ground, power return ground and 115 VAC.
DIMINSIONS
19" W x 8.70" H x 18" D (219x295x374 mm).
WEIGHT
33 lbs. net (15 kg); 42 lbs. shipping (19 kg).
AMBIENT
0°C to 50°C (32°F to 122°F).
POWER
115/230 V, ±10%, 50/60 Hz.

• Supplies Six DC Voltages
• Houses Up to Twelve Modules
• Front Panel Test Points
• Excessive Temperature Warning
• Field Proven Reliability
• Power Any BNC Plug-in Modules
• Make Up Compact Bench Systems
• Accepts All NIM Models
• Install Self-Built Instruments
• Relay Rack Installations
BNC-blue painted blank panels are available to cover unused module cavities.
The part numbers are: Single-width P/N 6823, Double-width P/N 6824, Triple-width
P/N 6826. Empty modules in various standard sizes are also available for those
who wish to build and install their own special or auxiliary instrumentation
in convenient plug-in form. Consult the factory for source information on
module kits.
Berkeley Nucleonics Corporation
2955 Kerner Blvd., San Rafael CA 94901 U.S.A
Phone: 800.234.7858 Fax: 415.453.9956
E-mail: info@berkeleynucleonics.com